CVE-2022-40656

This vulnerability allows remote attackers to execute arbitrary code on affected installations of NIKON NIS-Elements Viewer 13.2.0.21165. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ND2 files. Crafted data in a ND2 file can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15072.
References
Link Resource
https://www.zerodayinitiative.com/advisories/ZDI-22-1212/ Third Party Advisory VDB Entry
Configurations

Configuration 1

cpe:2.3:a:nikon:nis-elements_viewer:13.2.0.21165:*:*:*:*:*:*:*

Information

Published : 2022-09-15 04:15

Updated : 2022-09-17 03:43


NVD link : CVE-2022-40656

Mitre link : CVE-2022-40656

Products Affected
No products.
CWE
CWE-125

Out-of-bounds Read