A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3500 Platform Switches and Nexus 3000 Series Switches software versions prior to 7.0(3)I7(4) are affected.
cisco
CVE-2019-15990
A vulnerability in the web-based management interface of certain Cisco Small Business RV Series Routers could allow an unauthenticated, remote attacker to view information displayed in the web-based management interface. The vulnerability is due to improper authorization of HTTP requests. An attacker could exploit this vulnerability by sending crafted HTTP requests to the web-based management interface of an affected device. A successful exploit could allow the attacker to view information displayed in the web-based management interface without authentication.
CVE-2019-15993
A vulnerability in the web UI of Cisco Small Business Switches could allow an unauthenticated, remote attacker to access sensitive device information. The vulnerability exists because the software lacks proper authentication controls to information accessible from the web UI. An attacker could exploit this vulnerability by sending a malicious HTTP request to the web UI of an affected device. A successful exploit could allow the attacker to access sensitive device information, which includes configuration files.
CVE-2019-15998
A vulnerability in the access-control logic of the NETCONF over Secure Shell (SSH) of Cisco IOS XR Software may allow connections despite an access control list (ACL) that is configured to deny access to the NETCONF over SSH of an affected device. The vulnerability is due to a missing check in the NETCONF over SSH access control list (ACL). An attacker could exploit this vulnerability by connecting to an affected device using NETCONF over SSH. A successful exploit could allow the attacker to connect to the device on the NETCONF port. Valid credentials are required to access the device. This vulnerability does not affect connections to the default SSH process on the device.
CVE-2019-1600
A vulnerability in the file system permissions of Cisco FXOS Software and Cisco NX-OS Software could allow an authenticated, local attacker to access sensitive information that is stored in the file system of an affected system. The vulnerability is due to improper implementation of file system permissions. An attacker could exploit this vulnerability by accessing and modifying restricted files. A successful exploit could allow the attacker to access sensitive and critical files. Firepower 4100 Series Next-Generation Firewalls are affected in versions prior to 2.2.2.91 and 2.3.1.110. Firepower 9300 Series Next-Generation Firewalls are affected in versions prior to 2.2.2.91 and 2.3.1.110. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(25), 8.1(1b), and 8.3(1). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 6.0(2)A8(10) and 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected in versions prior to 7.1(5)N1(1b) and 7.3(3)N1(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3). Nexus 9000 Series Switches-Standalone are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
CVE-2019-16001
A vulnerability in the loading mechanism of specific dynamic link libraries in Cisco Webex Teams for Windows could allow an authenticated, local attacker to perform a DLL hijacking attack. To exploit this vulnerability, the attacker would need to have valid credentials on the Windows system. The vulnerability is due to insufficient validation of the resources loaded by the application at run time. An attacker could exploit this vulnerability by crafting a malicious DLL file and placing it in a specific location on the targeted system. The malicious DLL file would execute when the vulnerable application is launched. A successful exploit could allow the attacker to execute arbitrary code on the target machine with the privileges of another user account.