In IP-AK2 Access Control Panel Version 1.04.07 and prior, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.
honeywell
CVE-2021-39363
Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow a video replay attack after ARP cache poisoning has been achieved.
CVE-2021-39364
Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow command spoofing (for camera control) after ARP cache poisoning has been achieved.
CVE-2022-30318
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.