On Signify Philips Taolight Smart Wi-Fi Wiz Connected LED Bulb 9290022656 devices, an unprotected API lets remote users control the bulb’s operation. Anyone can turn the bulb on or off, or change its color or brightness remotely. There is no authentication or encryption to use the control API. The only requirement is that the attacker have network access to the bulb.
philips
CVE-2019-18241
In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. This could enable an unauthorized attacker with access to the network to capture and replay the session and gain unauthorized access to the EC40/80 hub.
CVE-2019-18263
An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016-August 2018), Veradius Unity (718132) with ViewForum option (shipped between 2016-August 2018), Pulsera (718095) and Endura (718075) with wireless option (shipped between 26-June-2017 through 07-August 2018), Pulsera (718095) and Endura (718075) with ViewForum option (shipped between 26-June-2017 through 07-August 2018). The router software uses an encryption scheme that is not strong enough for the level of protection required.
CVE-2019-13530
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware.
CVE-2019-13534
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.
CVE-2019-10988
In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product.