CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Cross-Site Request Forgery (CSRF) vulnerability in Sygnoos Popup Builder plugin <= 4.1.11 at WordPress allows an attacker to update plugin settings.
Improper input validation in firmware for OpenBMC in some Intel(R) platforms before versions egs-0.91-179 and bhs-04-45 may allow an authenticated user to potentially enable denial of service via network access.
Core_i7-6970hq_firmware, Core_i7-6970hq, Core_i7-6920hq_firmware, Core_i7-6920hq, Core_i7-6870hq_firmware, Core_i7-6870hq, Core_i7-6822eq_firmware, Core_i7-6822eq, Core_i7-6820hq_firmware, Core_i7-6820hq
2023-02-17
N/A
N/A
Uncaught exception in webserver for the Integrated BMC in some Intel(R) platforms before versions 2.86, 2.09 and 2.78 may allow a privileged user to potentially enable denial of service via network access.
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
On F5 BIG-IP LTM, Advanced WAF, ASM, or APM 16.1.x versions prior to 16.1.2.2, 15.1.x versions prior to 15.1.5, 14.1.x versions prior to 14.1.4.6, and all versions of 13.1.x, 12.1.x, and 11.6.x, when a virtual server is configured with HTTP, TCP on one side (client/server), and DTLS on the other (server/client), undisclosed requests can cause the TMM process to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
Altair HyperView Player versions 2021.1.0.27 and prior are vulnerable to the use of uninitialized memory vulnerability during parsing of H3D files. A DWORD is extracted from an uninitialized buffer and, after sign extension, is used as an index into a stack variable to increment a counter leading to memory corruption.
Cross-Site Request Forgery (CSRF) vulnerability in Sucuri Security plugin <= 1.8.33 at WordPress leading to Event log entry creation.
The affected product is vulnerable to an out-of-bounds read via uninitialized pointer, which may allow an attacker to execute arbitrary code.
Cross-site scripting vulnerability in Cybozu Office 10.0.0 to 10.8.5 allows a remote attacker to inject an arbitrary script via unspecified vectors.