CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
In 2345 Security Guard 3.6, the driver file (2345NetFirewall.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x00222040.
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
In Delta Electronics Automation TPEditor version 1.89 or prior, parsing a malformed program file may cause heap-based buffer overflow vulnerability, which may allow remote code execution.
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.
In Lantech IDS 2102 2.0 and prior, nearly all input fields allow for arbitrary input on the device. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can apply the other vulnerabilities within this advisory to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.
In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow a remote attacker to send specially crafted packets causing the device to become unavailable.
In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker on an adjacent network could perform command injection.
In Lantech IDS 2102 2.0 and prior, a stack-based buffer overflow vulnerability has been identified which may allow remote code execution. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
In ATI Systems Emergency Mass Notification Systems (HPSS16, HPSS32, MHPSS, and ALERT4000) devices, a missing encryption of sensitive data vulnerability caused by specially crafted malicious radio transmissions may allow an attacker to remotely trigger false alarms.