CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote attacker to execute arbitrary code on the device.
Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code.
A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A cleartext transmission of sensitive information vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an unquoted search path or element vulnerability that has been identified, which may allow an authorized local user to execute arbitrary code and escalate their level of privileges.
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An improper restriction of excessive authentication vulnerability in the web interface has been identified, which may allow an attacker to brute force authentication.
Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code
An Information Exposure Through Query Strings in GET Request issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An information exposure through query strings vulnerability in the web interface has been identified, which may allow an attacker to impersonate a legitimate user.
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.
A Session Fixation issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A session fixation vulnerability in the web interface has been identified, which may allow an attacker to hijack web sessions.
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an untrusted SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.