LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.
Reflected cross-site scripting (non-persistent) in SCADA WebServer (Versions prior to 2.03.0001) could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.
IBM InfoSphere Information Server 11.3, 11.5, and 11.7 could allow an attacker to change one of the settings related to InfoSphere Business Glossary Anywhere due to improper access control. IBM X-Force ID: 152528.
In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash.
VT-Designer Version 2.1.7.31 is vulnerable by the program populating objects with user supplied input via a file without first checking for validity, allowing attacker supplied input to be written to known memory locations. This may cause the program to crash or allow remote code execution.
LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.
Tridium Niagara Enterprise Security 2.3u1, all versions prior to 2.3.118.6, Niagara AX 3.8u4, all versions prior to 3.8.401.1, Niagara 4.4u2, all versions prior to 4.4.93.40.2, and Niagara 4.6, all versions prior to 4.6.96.28.4 a cross-site scripting vulnerability has been identified that may allow a remote attacker to inject code to some web pages affecting confidentiality.
Medtronic CareLink 2090 Programmer CareLink 9790 Programmer 29901 Encore Programmer, all versions, The affected products do not encrypt or do not sufficiently encrypt the following sensitive information while at rest PII and PHI.