CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
IBM DB2 for Linux, UNIX and Windows (includes DB2 Connect Server) 11.1 could allow a user to bypass FGAC control and gain access to data they shouldn't be able to see. IBM X-Force ID: 151155.
The Dundas BI server before 5.0.1.1010 is vulnerable to a Server-Side Request Forgery attack, allowing an attacker to forge arbitrary requests (with certain restrictions) that will be executed on behalf of the attacker, via the viewUrl parameter of the "export the dashboard as an image" feature. This could be leveraged to provide a proxy to attack other servers (internal or external) or to perform network scans of external or internal networks.
Unified_communications_software, Better_together_over_ethernet_connector, C12, C16, C8, Vvx150, Vvx201, Vvx250, Vvx301, Vvx311
2021-06-15
N/A
5.9 MEDIUM
Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business.
AudioCodes 440HD and 450HD devices 3.1.2.89 and earlier allows man-in-the-middle attackers to obtain sensitive credential information by leveraging failure to validate X.509 certificates when used with an on-premise installation with Skype for Business.
Unified_communications_software, Better_together_over_ethernet_connector, C12, C16, C8, Vvx150, Vvx201, Vvx250, Vvx301, Vvx311
2021-06-15
N/A
5.3 MEDIUM
The SIP service in Polycom VVX 500 and 601 devices 5.8.0.12848 and earlier allow remote attackers to obtain sensitive phone configuration information by leveraging use with an on-premise installation with Skype for Business.
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 (Serial number below KQ0400000 or KS0400000), and cobas h 232 before 04.00.04 (Serial number above KQ0400000 or KS0400000). A vulnerability in the software update mechanism allows authenticated attackers in the adjacent network to overwrite arbitrary files on the system through a crafted update package.
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 (Serial number above KQ0400000 or KS0400000). Improper access control allows attackers in the adjacent network to change the instrument configuration.
An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232 before 03.01.03 (Serial Number below KQ0400000 or KS0400000) and cobas h 232 before 04.00.04 (Serial Number above KQ0400000 or KS0400000). Improper access control to a service command allows attackers in the adjacent network to execute arbitrary code on the system through a crafted Poct1-A message.
An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Weak access credentials may enable attackers in the adjacent network to gain unauthorized service access via a service interface.
An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in the adjacent network to execute arbitrary commands on the operating system.