All versions of Telecrane F25 Series Radio Controls before 00.0A use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state.
NUUO CMS All versions 3.3 and prior the application allows external input to construct a pathname that is able to be resolved outside the intended directory. This could allow an attacker to impersonate a legitimate user, obtain restricted information, or execute arbitrary code.
VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) connected to the VGo XAMPP. User accounts may be able to execute commands that are outside the scope of their privileges and within the scope of an admin account. If an attacker has access to VGo XAMPP Client credentials, they may be able to execute admin commands on the connected robot.
JUUKO K-800 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.) is vulnerable to a replay attack and command forgery, which could allow attackers to replay commands, control the device, view commands, or cause the device to stop running.
If an attacker has physical access to the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be able to alter scripts, which may allow code execution with root privileges.
A stack-based buffer overflow vulnerability has been identified in Teledyne DALSA Sherlock Version 7.2.7.4 and prior, which may allow remote code execution.
IBM WebSphere Application Server 7.0, 8.0, 8.5, and 9.0 using SAML ear is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 148948.
In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files lacking user input validation before copying data from project files onto the stack and may allow an attacker to remotely execute arbitrary code.
The product CMS-770 (Software Versions 1.7.1 and prior)is vulnerable that an attacker can read sensitive configuration files by bypassing the user authentication mechanism.
In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files lacking user input validation, which may cause the system to write outside the intended buffer area and may allow remote code execution.