CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.
A CWE-88: Argument Injection or Modification vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause unauthorized write access when opening the project file.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access outside of expected path folder when opening the project file.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded.
**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4.
A CWE-426: Untrusted Search Path vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 15 and prior) and Vijeo Designer (V6.9 SP9 and prior), which could cause arbitrary code execution on the system running Vijeo Basic when a malicious DLL library is loaded by the Product.
Modicon_m221_firmware, Modicon_m221, Modicon_premium_firmware, Modicon_premium, Modicon_quantum_firmware, Modicon_quantum, Modicon_m340_firmware, Modicon_m340, Modicon_m580_firmware, Modicon_m580
2022-01-31
N/A
9.8 CRITICAL
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.