CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Insufficient output sanitization in Teltonika firmware TRB2_R_00.02.02 allows a remote, authenticated attacker to conduct persistent cross-site scripting (XSS) attacks by injecting malicious client-side code into the 'URL/ Host / Connection' form in the 'DATA TO SERVER' configuration section.
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') in Icegram Email Subscribers & Newsletters Plugin for WordPress v4.4.8 allows a remote, authenticated attacker to determine the value of database fields.
Cross-site request forgery in Icegram Email Subscribers & Newsletters Plugin for WordPress v4.4.8 allows a remote attacker to send forged emails by tricking legitimate users into clicking a crafted link.
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') in SRS Simple Hits Counter Plugin for WordPress 1.0.3 and 1.0.4 allows a remote, unauthenticated attacker to determine the value of database fields.
Nessus 8.10.0 and earlier were found to contain a Stored XSS vulnerability due to improper validation of input during scan configuration. An authenticated, remote attacker could potentially exploit this vulnerability to execute arbitrary code in a user's session. Tenable has implemented additional input validation mechanisms to correct this issue in Nessus 8.11.0.
MX Player Android App versions prior to v1.24.5, are vulnerable to a directory traversal vulnerability when user is using the MX Transfer feature in "Receive" mode. An attacker can exploit this by connecting to the MX Transfer session as a "sender" and sending a MessageType of "FILE_LIST" with a "name" field containing directory traversal characters (../). This will result in the file being transferred to the victim's phone, but being saved outside of the intended "/sdcard/MXshare" directory. In some instances, an attacker can achieve remote code execution by writing ".odex" and ".vdex" files in the "oat" directory of the MX Player application.
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.