Reflected cross-site scripting vulnerability in XooNIps 3.49 and earlier allows remote authenticated attackers to inject arbitrary script via unspecified vectors.
SQL injection vulnerability in the XooNIps 3.49 and earlier allows remote authenticated attackers to execute arbitrary SQL commands via unspecified vectors.
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.
Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
Uncontrolled resource consumption vulnerability in Ethernet Port on MELSEC iQ-R, Q and L series CPU modules (R 00/01/02 CPU firmware versions '20' and earlier, R 04/08/16/32/120 (EN) CPU firmware versions '52' and earlier, R 08/16/32/120 SFCPU firmware versions '22' and earlier, R 08/16/32/120 PCPU all versions, R 08/16/32/120 PSFCPU all versions, R 16/32/64 MTCPU all versions, Q03 UDECPU, Q 04/06/10/13/20/26/50/100 UDEHCPU serial number '22081' and earlier , Q 03/04/06/13/26 UDVCPU serial number '22031' and earlier, Q 04/06/13/26 UDPVCPU serial number '22031' and earlier, Q 172/173 DCPU all versions, Q 172/173 DSCPU all versions, Q 170 MCPU all versions, Q 170 MSCPU all versions, L 02/06/26 CPU (-P) and L 26 CPU - (P) BT all versions) allows a remote unauthenticated attacker to stop the Ethernet communication functions of the products via a specially crafted packet, which may lead to a denial of service (DoS) condition .
Accept_stripe, All_in_one_wp_security_&_firewall, Category_specific_rss_feed_subscription, Compact_wp_audio_player, Donations_via_paypal, Easy_accept_payments_for_paypal, Far_future_expiry_header, Simple_download_monitor, Software_license_manager, Wordpress_simple_paypal_shopping_cart
2020-10-27
N/A
8.8 HIGH
SQL injection vulnerability in Simple Download Monitor 3.8.8 and earlier allows remote attackers to execute arbitrary SQL commands via a specially crafted URL.