CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Resource Management Errors vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows an attacker on the same network segment to stop the network functions or execute malware via a specially crafted packet.
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to bypass access restriction and to stop the network functions or execute malware via a specially crafted packet.
Null Pointer Dereference vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
Open redirect vulnerability in CyberMail Ver.6.x and Ver.7.x allows remote attackers to redirect users to arbitrary sites and conduct phishing attacks via a specially crafted URL.
Cross-site scripting vulnerability in CyberMail Ver.6.x and Ver.7.x allows remote attackers to inject arbitrary script or HTML via a specially crafted URL.
GRANDIT Ver.1.6, Ver.2.0, Ver.2.1, Ver.2.2, Ver.2.3, and Ver.3.0 do not properly manage sessions, which allows remote attackers to impersonate an arbitrary user and then alter or disclose the information via unspecified vectors.
Improper Access Control in PALLET CONTROL Ver. 6.3 and earlier allows authenticated attackers to execute arbitrary code with the SYSTEM privilege on the computer where PALLET CONTROL is installed via unspecified vectors. PalletControl 7 to 9.1 are not affected by this vulnerability, however under the environment where PLS Management Add-on Module is used, all versions are affected.
