Philips SureSigns VS4, A.07.107 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
FPWIN Pro is vulnerable to an out-of-bounds read vulnerability when a user opens a maliciously crafted project file, which may allow an attacker to remotely execute arbitrary code.
Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained.
In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code.
An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.
In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file.
The affected Bachmann Electronic M-Base Controllers of version MSYS v1.06.14 and later use weak cryptography to protect device passwords. Affected controllers that are actively supported include MX207, MX213, MX220, MC206, MC212, MC220, and MH230 hardware controllers, and affected end-of-life controller include MC205, MC210, MH212, ME203, CS200, MP213, MP226, MPC240, MPC265, MPC270, MPC293, MPE270, and CPC210 hardware controllers. Security Level 0 is set at default from the manufacturer, which could allow an unauthenticated remote attacker to gain access to the password hashes. Security Level 4 is susceptible if an authenticated remote attacker or an unauthenticated person with physical access to the device reads and decrypts the password to conduct further attacks.
2021-11-22
N/A
2.3 LOW
All version of Ewon Flexy and Cosy prior to 14.1 use wildcards such as (*) under which domains can request resources. An attacker with local access and high privileges could inject scripts into the Cross-origin Resource Sharing (CORS) configuration that could abuse this vulnerability, allowing the attacker to retrieve limited confidential information through sniffing.
A local, authenticated user with shell can view sensitive configuration information via the ev.ops configuration file. This issue affects all versions of Junos OS Evolved prior to 19.2R1.
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.