CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
A local, authenticated user with shell can obtain the hashed values of login passwords via configd traces. This issue affects all versions of Junos OS Evolved prior to 19.3R1.
A malicious attacker could exploit the interface of the Fieldcomm Group HART-IP (release 1.0.0.0) by constructing messages with sufficiently large payloads to overflow the internal buffer and crash the device, or obtain control of the device.
The affected product is vulnerable to cross-site request forgery, which may allow an attacker to modify different configurations of a device by luring an authenticated user to click on a crafted link on the N-Tron 702-W / 702M12-W (all versions).
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by opening specially crafted project files that may overflow the heap, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
The affected product is vulnerable to stored cross-site scripting, which may allow an attacker to remotely execute arbitrary code to gain access to sensitive data on the N-Tron 702-W / 702M12-W (all versions).
Using a specially crafted URL command, a remote authenticated user can execute commands as root on the G-Cam and G-Code (Firmware Versions 1.12.0.25 and prior as well as the limited Versions 1.12.13.2 and 1.12.14.5).
The affected product is vulnerable due to an undocumented interface found on the device, which may allow an attacker to execute commands as root on the device on the N-Tron 702-W / 702M12-W (all versions).
Asda_soft, Cncsoft, Cncsoft-b, Cncsoft_screeneditor, Cnssoft_screeneditor, Commgr, Dcisoft, Delta_industrial_automation_dopsoft, Delta_industrial_automation_pmsoft, Delta_industrial_automation_screen_editor
2020-08-06
N/A
7.8 HIGH
Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. An uninitialized pointer may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
WebAccess Node (All versions prior to 9.0.1) has incorrect permissions set for resources used by specific services, which may allow code execution with system privileges.
Asda_soft, Cncsoft, Cncsoft-b, Cncsoft_screeneditor, Cnssoft_screeneditor, Commgr, Dcisoft, Delta_industrial_automation_dopsoft, Delta_industrial_automation_pmsoft, Delta_industrial_automation_screen_editor
2020-08-06
N/A
3.3 LOW
Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information.
