Wl-wn575a3_firmware, Wl-wn575a3, Wl-wn530hg4_firmware, Wl-wn530hg4, Wl-wn579g3_firmware, Wl-wn579g3, Wn530hg4_firmware, Wn530hg4, Wn531g3_firmware, Wn531g3
2021-07-21
N/A
9.8 CRITICAL
An issue was discovered on Wavlink WL-WN530HG4 M30HG4.V5030.191116 devices. Multiple shell metacharacter injection vulnerabilities exist in CGI scripts, leading to remote code execution with root privileges.
Re:Desk 2.3 allows insecure file upload.
Re:Desk 2.3 contains a blind unauthenticated SQL injection vulnerability in the getBaseCriteria() function in the protected/models/Ticket.php file. By modifying the folder GET parameter, it is possible to execute arbitrary SQL statements via a crafted URL. Unauthenticated remote command execution is possible by using this SQL injection to update certain database values, which are then executed by a bizRule eval() function in the yii/framework/web/auth/CAuthManager.php file. Resultant authorization bypass is also possible, by recovering or modifying password hashes and password reset tokens, allowing for administrative privileges to be obtained.
An issue was discovered on Dr Trust ECG Pen 2.00.08 devices. Because the Bluetooth LE support is implemented without a requirement for pairing or security, any attacker can access the GATT server of the device and can sniff the data being broadcasted while a measurement is being done. Also, saved data can also be extracted over a Bluetooth connection. In addition, an attacker can launch a man-in-the-middle attack against data integrity.
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering.
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering.
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access.
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network.
An issue was discovered in PassMark BurnInTest v9.1 Build 1008, OSForensics v7.1 Build 1012, and PerformanceTest v10.0 Build 1008. The kernel driver exposes IOCTL functionality that allows low-privilege users to map arbitrary physical memory into the address space of the calling process. This could lead to arbitrary Ring-0 code execution and escalation of privileges. This affects DirectIo32.sys and DirectIo64.sys drivers. This issue is fixed in BurnInTest v9.2, PerformanceTest v10.0 Build 1009, OSForensics v8.0.
An issue was discovered in PassMark BurnInTest through 9.1, OSForensics through 7.1, and PerformanceTest through 10. The kernel driver exposes IOCTL functionality that allows low-privilege users to read and write to arbitrary Model Specific Registers (MSRs). This could lead to arbitrary Ring-0 code execution and escalation of privileges. This affects DirectIo32.sys and DirectIo64.sys.