• Skip to primary navigation
  • Skip to main content
CVE Vulnerability

CVE Vulnerability

  • CVE’s
  • Products
  • Vendors
Home » CVE’s

CVE’s


CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
CVE-2019-7738
2019-02-13
N/A
6.5 MEDIUM
C.P.Sub before 5.3 allows CSRF via a manage.php?p=article_del&id= URI.
CVE-2019-7737
2019-02-12
N/A
8.8 HIGH
A CSRF vulnerability was found in Verydows v2.0 that can add an admin account via index.php?m=backend&c=admin&a=add&step=submit.
CVE-2019-7736
Dir-600m Firmware, Dlink
Dir-816_firmware, Dir-816, Dsl-2750u_firmware, Dsl-2750u, Dir-806_firmware, Dir-806, Dcs-930l_firmware, Dcs-930l, Dcs-931l_firmware, Dcs-931l
2020-08-24
N/A
9.8 CRITICAL
D-Link DIR-600M C1 3.04 devices allow authentication bypass via a direct request to the wan.htm page. NOTE: this may overlap CVE-2019-13101.
CVE-2019-7733
2020-05-15
N/A
7.5 HIGH
In Live555 0.95, there is a buffer overflow via a large integer in a Content-Length HTTP header because handleRequestBytes has an unrestricted memmove.
CVE-2019-7732
2020-08-24
N/A
7.5 HIGH
In Live555 0.95, a setup packet can cause a memory leak leading to DoS because, when there are multiple instances of a single field (username, realm, nonce, uri, or response), only the last instance can ever be freed.
CVE-2019-7731
2021-07-21
N/A
9.8 CRITICAL
MyWebSQL 3.7 has a remote code execution (RCE) vulnerability after an attacker writes shell code into the database, and executes the Backup Database function with a .php filename for the backup's archive file.
CVE-2019-7730
2019-02-12
N/A
5.7 MEDIUM
MyWebSQL 3.7 has a Cross-site request forgery (CSRF) vulnerability for deleting a database via the /?q=wrkfrm&type=databases URI.
CVE-2019-7729
2020-08-24
N/A
3.3 LOW
An issue was discovered in the Bosch Smart Camera App before 1.3.1 for Android. Due to setting of insecure permissions, a malicious app could potentially succeed in retrieving video clips or still images that have been cached for clip sharing. (The Bosch Smart Home App is not affected. iOS Apps are not affected.)
CVE-2019-7728
2019-02-22
N/A
7.5 HIGH
An issue was discovered in the Bosch Smart Camera App before 1.3.1 for Android. Due to improperly implemented TLS certificate checks, a malicious actor could potentially succeed in executing a man-in-the-middle attack for some connections. (The Bosch Smart Home App is not affected. iOS Apps are not affected.)
CVE-2019-7727
2020-08-24
N/A
9.8 CRITICAL
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
« Previous 1 … 5,233 5,234 5,235 5,236 5,237 … 11,258 Next »

Copyright CVE Vulnerabilities 2023
Data Sources:

  • NIST
  • MITRE
  • CVE Search
  • Open CVE