CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Symonics libmysofa 0.7 has a NULL pointer dereference in getHrtf in hrtf/reader.c.
Symonics libmysofa 0.7 has an out-of-bounds read in directblockRead in hdf/fractalhead.c.
Sd-wan_firmware, Vedge-100, Vedge-1000, Vedge-100b, Vedge-2000, Vedge-5000, Vedge_100m, Vedge_100wm, Hyperflex_hx220c_m5_firmware, Hyperflex_hx220c_m5
2020-10-05
N/A
6.7 MEDIUM
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(2). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(6). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(6). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), 8.2(3), and 8.3(2). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I4(9) and7.0(3)I7(6). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
An issue was discovered in the Linux kernel through 5.2.13. nbd_genl_status in drivers/block/nbd.c does not check the nla_nest_start_noflag return value.
Xpdf 3.04 has a SIGSEGV in XRef::fetch in XRef.cc after many recursive calls to Catalog::countPageTree in Catalog.cc.
Sd-wan_firmware, Vedge-100, Vedge-1000, Vedge-100b, Vedge-2000, Vedge-5000, Vedge_100m, Vedge_100wm, Hyperflex_hx220c_m5_firmware, Hyperflex_hx220c_m5
2020-10-05
N/A
6.7 MEDIUM
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).
An OS command injection vulnerability in the discover_and_manage CGI script in NETSAS Enigma NMS 65.0.0 and prior allows an attacker to execute arbitrary code because of improper neutralization of shell metacharacters in the ip_address variable within an snmp_browser action.
Enigma NMS 65.0.0 and prior allows administrative users to create low-privileged accounts that do not have the ability to modify any settings in the system, only view the components. However, it is possible for a low-privileged user to perform all actions as an administrator by bypassing authorization controls and sending requests to the server in the context of an administrator.
A number of stored Cross-site Scripting (XSS) vulnerabilities were identified in NETSAS Enigma NMS 65.0.0 and prior that could allow a threat actor to inject malicious code directly into the application through web application form inputs.
Sd-wan_firmware, Vedge-100, Vedge-1000, Vedge-100b, Vedge-2000, Vedge-5000, Vedge_100m, Vedge_100wm, Hyperflex_hx220c_m5_firmware, Hyperflex_hx220c_m5
2020-10-05
N/A
6.7 MEDIUM
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).
