CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Logo!8_bm_firmware, Logo!8_bm, Cp1604_firmware, Cp1604, Cp1616_firmware, Cp1616, Dk_standard_ethernet_controller_firmware, Dk_standard_ethernet_controller, Ek-ertec_200_firmware, Ek-ertec_200
2022-05-20
N/A
7.1 HIGH
A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Series (BACnet) (All versions < V3.5.3), APOGEE PXC Series (P2) (All versions >= V2.8.2 and < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC100-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC12-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC22-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC22.1-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC36.1-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC50-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3x and < V6.00.327), Nucleus NET (All versions), Nucleus RTOS (All versions), Nucleus ReadyStart for ARM, MIPS, and PPC (All versions < V2017.02.2 with patch "Nucleus 2017.02.02 Nucleus NET Patch"), Nucleus SafetyCert (All versions), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Series (BACnet) (All versions < V3.5.3), VSTAR (All versions). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value. The vulnerability could affect availability and integrity of the device. Adjacent network access is required, but no authentication and no user interaction is needed to conduct an attack.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
Logo!8_bm_firmware, Logo!8_bm, Cp1604_firmware, Cp1604, Cp1616_firmware, Cp1616, Dk_standard_ethernet_controller_firmware, Dk_standard_ethernet_controller, Ek-ertec_200_firmware, Ek-ertec_200
2022-12-13
N/A
8.6 HIGH
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web application requests could be manipulated, causing the the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated. A successful attack could allow the import of scripts or generation of malicious links. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
20007_office_system, 27mhz_wireless_keyboard, 365_apps, 3d_builder, 3d_viewer, Access, Accessibility_insights_for_android, Accessibility_insights_for_web, Access_multilingual_user_interface_pack, Active_directory
2020-08-24
N/A
7.8 HIGH
An elevation of privilege vulnerability exists in Windows when the Win32k component fails to properly handle objects in memory, aka 'Win32k Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1394, CVE-2019-1395, CVE-2019-1396, CVE-2019-1408, CVE-2019-1434.
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.