CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.
In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
Electric_fr_configurator2_firmware, Electric_fr_configurator2, Qj71e71-100_firmware, Qj71e71-100, Q03/04/06/13/26udvcpu_firmware, Q03/04/06/13/26udvcpu, Q04/06/13/26udpvcpu_firmware, Q04/06/13/26udpvcpu, Q03udecpu_firmware, Q03udecpu
2019-11-18
N/A
5.9 MEDIUM
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service.
2020-02-10
N/A
9.8 CRITICAL
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.
In WebAccess versions 8.4.1 and prior, multiple command injection vulnerabilities are caused by a lack of proper validation of user-supplied data and may allow arbitrary file deletion and remote code execution.
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. Path traversal vulnerabilities are caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage these vulnerabilities to remotely execute code while posing as an administrator.
In WebAccess, versions 8.4.1 and prior, an improper authorization vulnerability may allow an attacker to disclose sensitive information, cause improper control of generation of code, which may allow remote code execution or cause a system crash.
** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2019. Notes: none.
2020-02-10
N/A
7.5 HIGH
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.