• Skip to primary navigation
  • Skip to main content
CVE Vulnerability

CVE Vulnerability

  • CVE’s
  • Products
  • Vendors
Home » CVE’s

CVE’s


CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
CVE-2019-10996
2019-10-09
N/A
7.8 HIGH
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that can reference memory after it has been freed.
CVE-2019-10995
Abb, Cp676-web Firmware
Pm554-tp-eth_firmware, Pm554-tp-eth, Cp651_firmware, Cp651, Cp651-web_firmware, Cp651-web, Cp661-web_firmware, Cp661-web, Cp661_firmware, Cp661
2020-01-24
N/A
8.8 HIGH
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.
CVE-2019-10994
2019-10-09
N/A
3.3 LOW
Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).
CVE-2019-10993
2022-04-18
N/A
9.8 CRITICAL
In WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code.
CVE-2019-10992
Cnssoft Screeneditor, Deltaww
Asda_soft, Cncsoft, Cncsoft-b, Cncsoft_screeneditor, Cnssoft_screeneditor, Commgr, Dcisoft, Delta_industrial_automation_dopsoft, Delta_industrial_automation_pmsoft, Delta_industrial_automation_screen_editor
2019-10-09
N/A
5.5 MEDIUM
Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple out-of-bounds read vulnerabilities may cause information disclosure due to lacking user input validation for processing project files.
CVE-2019-10991
2020-08-24
N/A
9.8 CRITICAL
In WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
CVE-2019-10990
2019-10-09
N/A
6.5 MEDIUM
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files.
CVE-2019-1099
2020-09-28
N/A
6.5 MEDIUM
An information disclosure vulnerability exists when the Windows GDI component improperly discloses the contents of its memory, aka 'Windows GDI Information Disclosure Vulnerability'. This CVE ID is unique from CVE-2019-1094, CVE-2019-1095, CVE-2019-1098, CVE-2019-1100, CVE-2019-1101, CVE-2019-1116.
CVE-2019-10989
2020-08-24
N/A
9.8 CRITICAL
In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.
CVE-2019-10988
Hdi 4000 Firmware, Philips
Hdi_4000_firmware, Hdi_4000, Intellivue_mp_monitors_mp20-mp90_firmware, M80010a, M8001a, M8002a, M8003a, M8004a, M8005a, M8007a
2020-10-02
N/A
3.4 LOW
In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product.