CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
A missing permission check in Jenkins JX Resources Plugin 1.0.36 and earlier in GlobalPluginConfiguration#doValidateClient allowed users with Overall/Read access to have Jenkins connect to an attacker-specified Kubernetes server, potentially leaking credentials.
A cross-site request forgery vulnerability in Jenkins JX Resources Plugin 1.0.36 and earlier in GlobalPluginConfiguration#doValidateClient allowed attackers to have Jenkins connect to an attacker-specified Kubernetes server, potentially leaking credentials.
An XML external entities (XXE) vulnerability in Jenkins Token Macro Plugin 2.7 and earlier allowed attackers able to control a the content of the input file for the "XML" macro to have Jenkins resolve external entities, resulting in the extraction of secrets from the Jenkins agent, server-side request forgery, or denial-of-service attacks.
A reflected cross site scripting vulnerability in Jenkins ElectricFlow Plugin 1.1.6 and earlier allowed attackers able to control the output of the ElectricFlow API to inject arbitrary HTML and JavaScript in job configuration forms containing post-build steps provided by this plugin.
A stored cross site scripting vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier allowed attackers able to configure jobs in Jenkins or control the output of the ElectricFlow API to inject arbitrary HTML and JavaScript in the plugin-provided output on build status pages.
Jenkins ElectricFlow Plugin 1.1.5 and earlier disabled SSL/TLS and hostname verification globally for the Jenkins master JVM when MultipartUtility.java is used to upload files.
Missing permission checks in Jenkins ElectricFlow Plugin 1.1.5 and earlier in various HTTP endpoints allowed users with Overall/Read access to obtain information about the Jenkins ElectricFlow Plugin configuration and configuration of connected ElectricFlow instances.
A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.
A cross-site request forgery vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed attackers to connect to an attacker-specified URL using attacker-specified credentials.
Jenkins Gitea Plugin 1.1.1 and earlier did not implement trusted revisions, allowing attackers without commit access to the Git repo to change Jenkinsfiles even if Jenkins is configured to consider them to be untrusted.
