CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
The uri-block plugin in Apache APISIX before 2.10.2 uses $request_uri without verification. The $request_uri is the full original request URI without normalization. This makes it possible to construct a URI to bypass the block list on some occasions. For instance, when the block list contains "^/internal/", a URI like `//internal/` can be used to bypass it. Some other plugins also have the same issue. And it may affect the developer's custom plugin.
FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code.
mySCADA myDESIGNER Versions 8.20.0 and prior fails to properly validate contents of an imported project file, which may make the product vulnerable to a path traversal payload. This vulnerability may allow an attacker to plant files on the file system in arbitrary locations or overwrite existing files, resulting in remote code execution.
FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
PI Vision could disclose information to a user with insufficient privileges for an AF attribute that is the child of another attribute and is configured as a Limits property.
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
A remote attacker with write access to PI Vision could inject code into a display. Unauthorized information disclosure, modification, or deletion is possible if a victim views or interacts with the infected display using Microsoft Internet Explorer. The impact affects PI System data and other data accessible with victim's user permissions.
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.
A remote authenticated attacker with write access to a PI Server could trick a user into interacting with a PI Web API endpoint and redirect them to a malicious website. As a result, a victim may disclose sensitive information to the attacker or be provided with false information.
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.