CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 is vulnerable to reflected cross-site scripting attacks. An attacker could inject JavaScript in a GET parameter of HTTP requests and perform unauthorized actions such as stealing internal information and performing actions in context of an authenticated user.
Core_i7-6970hq_firmware, Core_i7-6970hq, Core_i7-6920hq_firmware, Core_i7-6920hq, Core_i7-6870hq_firmware, Core_i7-6870hq, Core_i7-6822eq_firmware, Core_i7-6822eq, Core_i7-6820hq_firmware, Core_i7-6820hq
2022-08-19
N/A
7.8 HIGH
Improper buffer restrictions in firmware for some Intel(R) Wireless Bluetooth(R) and Killer(TM) Bluetooth(R) products before version 22.120 may allow an authenticated user to potentially enable escalation of privilege via local access.
Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 issues authentication tokens to authenticated users that are signed with a symmetric encryption key. An attacker in possession of the key can issue valid JWTs and impersonate arbitrary users.
The Splunk Enterprise REST API allows enumeration of usernames via the lockout error message. The potential vulnerability impacts Splunk Enterprise instances before 8.1.7 when configured to repress verbose login errors.
A floating point exception (divide-by-zero) issue was discovered in SoX in functon startread() of wav.c file. An attacker with a crafted wav file, could cause an application to crash.
Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings.
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges.
The server in Luca through 1.1.14 allows remote attackers to cause a denial of service (insertion of many fake records related to COVID-19) because Phone Number data lacks a digital signature.
A vulnerability in Stormshield Network Security could allow an attacker to trigger a protection related to ARP/NDP tables management, which would temporarily prevent the system to contact new hosts via IPv4 or IPv6. This affects versions 2.0.0 to 2.7.7, 2.8.0 to 2.16.0, 3.0.0 to 3.7.16, 3.8.0 to 3.11.4, and 4.0.0 to 4.1.5. Fixed in versions 2.7.8, 3.7.17, 3.11.5, and 4.2.0.