CVE-2021-33018
2022-04-08
N/A
7.5 HIGH
The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information.
CVE-2021-33017
Intellibridge Ec80 Firmware, Philips
Hdi_4000_firmware, Hdi_4000, Intellivue_mp_monitors_mp20-mp90_firmware, M80010a, M8001a, M8002a, M8003a, M8004a, M8005a, M8007a
2022-01-10
N/A
8.8 HIGH
The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication.
CVE-2021-33016
Kr C4 Firmware, Kuka
Kr_c4_firmware, Kr_c4
2022-06-08
N/A
9.8 CRITICAL
An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
CVE-2021-33015
2021-09-01
N/A
7.8 HIGH
Cscape (All Versions prior to 9.90 SP5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds write via an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-33014
Kr C4 Firmware, Kuka
Kr_c4_firmware, Kr_c4
2022-06-08
N/A
8.8 HIGH
An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
CVE-2021-33013
2022-10-27
N/A
7.5 HIGH
mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information.
CVE-2021-33012
Micrologix 1100 Firmware, Rockwellautomation
Compactlogix_5370_l1_firmware, Compactlogix_5370_l1, Compactlogix_5370_l2_firmware, Compactlogix_5370_l2, Compactlogix_5370_l3_firmware, Compactlogix_5370_l3, Armor_compact_guardlogix_5370_firmware, Armor_compact_guardlogix_5370, Compact_guardlogix_5370_firmware, Compact_guardlogix_5370
2021-07-12
N/A
8.6 HIGH
Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault whenever the controller is switched to RUN mode.
CVE-2021-33011
2021-09-23
N/A
4.3 MEDIUM
All versions of the afffected TOYOPUC-PC10 Series,TOYOPUC-Plus Series,TOYOPUC-PC3J/PC2J Series, TOYOPUC-Nano Series products may not be able to properly process an ICMP flood, which may allow an attacker to deny Ethernet communications between affected devices.
CVE-2021-33010
2022-04-13
N/A
7.5 HIGH
An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition.
CVE-2021-33009
2022-05-24
N/A
7.5 HIGH
mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to the file system.