Null pointer dereference in SuiteLink server while processing command 0x0b
After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly.
AVEVA System Platform versions 2017 through 2020 R2 P01 does not properly verify that the source of data or communication is valid.
All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization.
A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICEMSSQLSERVER.
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange.
AVEVA System Platform versions 2017 through 2020 R2 P01 uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the software does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active.
Collabtive 3.1 allows XSS when an authenticated user enters an XSS payload into the address section of the profile edit page, aka the manageuser.php?action=edit address1 parameter.
Null pointer dereference in SuiteLink server while processing commands 0x04/0x0a