CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
An issue was discovered in Pillow before 8.2.0. For BLP data, BlpImagePlugin did not properly check that reads (after jumping to file offsets) returned data. This could lead to a DoS where the decoder could be run a large number of times on empty data.
An issue was discovered in Pillow before 8.2.0. For EPS data, the readline implementation used in EPSImageFile has to deal with any combination of r and n as line endings. It used an accidentally quadratic method of accumulating lines while looking for a line ending. A malicious EPS file could use this to perform a DoS of Pillow in the open phase, before an image was accepted for opening.
An issue was discovered in Pillow before 8.2.0. For FLI data, FliDecode did not properly check that the block advance was non-zero, potentially leading to an infinite loop on load.
An issue was discovered in Pillow before 8.2.0. PSDImagePlugin.PsdImageFile lacked a sanity check on the number of input layers relative to the size of the data block. This could lead to a DoS on Image.open prior to Image.load.
The node management page in SolarWinds Orion Platform before 2020.2.5 HF1 allows an attacker to create or delete a node (outside of the attacker's perimeter) via an account with write permissions. This occurs because node IDs are predictable (with incrementing numbers) and the access control on Services/NodeManagement.asmx/DeleteObjNow is incorrect. To exploit this, an attacker must be authenticated and must have node management rights associated with at least one valid group on the platform.
Xerox Phaser 6510 before 64.61.23 and 64.59.11 (Bridge), WorkCentre 6515 before 65.61.23 and 65.59.11 (Bridge), VersaLink B400 before 37.61.23 and 37.59.01 (Bridge), B405 before 38.61.23 and 38.59.01 (Bridge), B600/B610 before 32.61.23 and 32.59.01 (Bridge), B605/B615 before 33.61.23 and 33.59.01 (Bridge), B7025/30/35 before 58.61.23 and 58.59.11 (Bridge), C400 before 67.61.23 and 67.59.01 (Bridge), C405 before 68.61.23 and 68.59.01 (Bridge), C500/C600 before 61.61.23 and 61.59.01 (Bridge), C505/C605 before 62.61.23 and 62.59.11 (Bridge), C7000 before 56.61.23 and 56.59.01 (Bridge), C7020/25/30 before 57.61.23 and 57.59.01 (Bridge), C8000/C9000 before 70.61.23 and 70.59.01 (Bridge), allows remote attackers with "a weaponized clone file" to execute arbitrary commands in the Web User Interface.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 allows remote attackers to execute arbitrary code through a buffer overflow in Web page parameter handling.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 have a remote Command Execution vulnerability in the Web User Interface that allows remote attackers with "a weaponized clone file" to execute arbitrary commands.
Colorqube_8700_firmware, Colorqube_8700, Colorqube_8900_firmware, Colorqube_8900, Colorqube_9301_firmware, Colorqube_9301, Colorqube_9302_firmware, Colorqube_9302, Colorqube_9303_firmware, Colorqube_9303
2021-04-01
N/A
9.1 CRITICAL
Xerox AltaLink B8045/B8090 before 103.008.030.32000, C8030/C8035 before 103.001.030.32000, C8045/C8055 before 103.002.030.32000 and C8070 before 103.003.030.32000 allow unauthorized users, by leveraging the Scan To Mailbox feature, to delete arbitrary files from the disk.
Colorqube_8700_firmware, Colorqube_8700, Colorqube_8900_firmware, Colorqube_8900, Colorqube_9301_firmware, Colorqube_9301, Colorqube_9302_firmware, Colorqube_9302, Colorqube_9303_firmware, Colorqube_9303
2021-04-01
N/A
7.5 HIGH
Xerox AltaLink B80xx before 103.008.020.23120, C8030/C8035 before 103.001.020.23120, C8045/C8055 before 103.002.020.23120 and C8070 before 103.003.020.23120 provide the ability to set configuration attributes without administrative rights.