CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Upload data forms do not correctly render user input leading to possible XSS attack vectors that can be performed by authenticated users with database connection update permissions. This issue affects Apache Superset version 1.5.2 and prior versions and version 2.0.0.
Dashboard rendering does not sufficiently sanitize the content of markdown components leading to possible XSS attack vectors that can be performed by authenticated users with create dashboard permissions. This issue affects Apache Superset version 1.5.2 and prior versions and version 2.0.0.
The Web Invoice WordPress plugin through 2.1.3 does not properly sanitize and escape a parameter before using it in a SQL statement, leading to a SQL Injection exploitable by high privilege users such as admin by default. However, depending on the plugin configuration, other users, such as subscriber could exploit this as well
MyBB 1.8.31 has a SQL injection vulnerability in the Admin CP's Users module allows remote authenticated users to modify the query string via direct user input or stored search filter settings.
MyBB 1.8.31 has a (issue 2 of 2) cross-site scripting (XSS) vulnerabilities in the post Attachments interface allow attackers to inject HTML by persuading the user to upload a file with specially crafted name
MyBB 1.8.31 has a Cross-site scripting (XSS) vulnerability in the visual MyCode editor (SCEditor) allows remote attackers to inject HTML via user input or stored data
Cross-site scripting (XSS) vulnerability in the Web UI of StackStorm versions prior to 3.8.0 allowed logged in users with write access to pack rules to inject arbitrary script or HTML that may be executed in Web UI for other logged in users.
In Botan before 2.19.3, it is possible to forge OCSP responses due to a certificate verification error. This issue was introduced in Botan 1.11.34 (November 2016).
The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the target device's physical environment.
The multimedial images WordPress plugin through 1.0b does not properly sanitize and escape a parameter before using it in a SQL statement, leading to a SQL injection exploitable by users with a role as low as Admin.
