There was a Memory Corruption issue discovered in multiple models of Axis IP Cameras which allows remote attackers to cause a denial of service (crash) by sending a crafted command which will result in a code path that calls the UND undefined ARM instruction.
CWE-119
CVE-2018-10664
An issue was discovered in the httpd process in multiple models of Axis IP Cameras. There is Memory Corruption.
CVE-2018-10594
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
CVE-2018-10617
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length heap buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash.
CVE-2018-10621
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length stack buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash.
CVE-2018-10628
AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process.