SAP NetWeaver AS for ABAP (RFC Gateway), versions – KRNL32NUC – 7.22,7.22EXT, KRNL64NUC – 7.22,7.22EXT,7.49, KRNL64UC – 8.04,7.22,7.22EXT,7.49,7.53,7.73, KERNEL – 7.22,8.04,7.49,7.53,7.73,7.77,7.81,7.82,7.83, allows an unauthenticated attacker without specific knowledge of the system to send a specially crafted packet over a network which will trigger an internal error in the system due to improper input validation in method memmove() causing the system to crash and rendering it unavailable. In this attack, no data in the system can be viewed or modified.
CWE-125
CVE-2021-27606
SAP NetWeaver ABAP Server and ABAP Platform (Enqueue Server), versions – KRNL32NUC – 7.22,7.22EXT, KRNL64NUC – 7.22,7.22EXT,7.49, KRNL64UC – 8.04,7.22,7.22EXT,7.49,7.53,7.73, KERNEL – 7.22,8.04,7.49,7.53,7.73, allows an unauthenticated attacker without specific knowledge of the system to send a specially crafted packet over a network which will trigger an internal error in the system due to improper input validation in method EncOAMParamStore() causing the system to crash and rendering it unavailable. In this attack, no data in the system can be viewed or modified.
CVE-2021-27482
A specifically crafted packet sent by an attacker to EIPStackGroup OpENer EtherNet/IP commits and versions prior to Feb 10, 2021 may allow the attacker to read arbitrary data.
CVE-2021-27490
Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
CVE-2021-27408
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
CVE-2021-27412
Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.