On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the traceroute utility integrated in the WebUI to execute arbitrary code with root privileges on the OS due to an improper input validation in all versions of the firmware.
CWE-20
CVE-2022-29613
Due to insufficient input validation, SAP Employee Self Service allows an authenticated attacker with user privileges to alter employee number. On successful exploitation, the attacker can view personal details of other users causing a limited impact on confidentiality of the application.
CVE-2022-29492
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
CVE-2022-29499
The Service Appliance component in Mitel MiVoice Connect through 19.2 SP3 allows remote code execution because of incorrect data validation. The Service Appliances are SA 100, SA 400, and Virtual SA.
CVE-2022-29539
resi-calltrace in RESI Gemini-Net 4.2 is affected by OS Command Injection. It does not properly check the parameters sent as input before they are processed on the server. Due to the lack of validation of user input, an unauthenticated attacker can bypass the syntax intended by the software (e.g., concatenate `&|;r commands) and inject arbitrary system commands with the privileges of the application user.
CVE-2022-29466
Improper input validation in firmware for Intel(R) SPS before version SPS_E3_04.01.04.700.0 may allow an authenticated user to potentially enable denial of service via local access.