Some Huawei products Agassi-L09 AGS-L09C100B257CUSTC100D001, AGS-L09C170B253CUSTC170D001, AGS-L09C199B251CUSTC199D001, AGS-L09C229B003CUSTC229D001, Agassi-W09 AGS-W09C100B257CUSTC100D001, AGS-W09C128B252CUSTC128D001, AGS-W09C170B252CUSTC170D001, AGS-W09C229B251CUSTC229D001, AGS-W09C331B003CUSTC331D001, AGS-W09C794B001CUSTC794D001, Baggio2-U01A BG2-U01C100B160CUSTC100D001, BG2-U01C170B160CUSTC170D001, BG2-U01C199B162CUSTC199D001, BG2-U01C209B160CUSTC209D001, BG2-U01C333B160CUSTC333D001, Bond-AL00C Bond-AL00CC00B201, Bond-AL10B Bond-AL10BC00B201, Bond-TL10B Bond-TL10BC01B201, Bond-TL10C Bond-TL10CC01B131, Haydn-L1JB HDN-L1JC137B068, Kobe-L09A KOB-L09C100B252CUSTC100D001, KOB-L09C209B002CUSTC209D001, KOB-L09C362B001CUSTC362D001, Kobe-L09AHN KOB-L09C233B226, Kobe-W09C KOB-W09C128B251CUSTC128D001, LelandP-L22C 8.0.0.101(C675CUSTC675D2), LelandP-L22D 8.0.0.101(C675CUSTC675D2), Rhone-AL00 Rhone-AL00C00B186, Selina-L02 Selina-L02C432B153, Stanford-L09S Stanford-L09SC432B183, Toronto-AL00 Toronto-AL00C00B223, Toronto-AL00A Toronto-AL00AC00B223, Toronto-TL10 Toronto-TL10C01B223 have a sensitive information leak vulnerability. An attacker can trick a user to install a malicious application to exploit this vulnerability. Due to insufficient verification of the input, successful exploitation can cause sensitive information leak.
CWE-200
CVE-2018-7921
Huawei B315s-22 products with software of 21.318.01.00.26 have an information leak vulnerability. Unauthenticated adjacent attackers may exploit this vulnerability to obtain device information.
CVE-2018-7930
The Near Field Communication (NFC) module in Mate 9 Huawei mobile phones with the versions before MHA-L29B 8.0.0.366(C567) has an information leak vulnerability due to insufficient validation on data transfer requests. When an affected mobile phone sends files to an attacker’s mobile phone using the NFC function, the attacker can obtain arbitrary files from the mobile phone, causing information leaks.
CVE-2018-7900
There is an information leak vulnerability in some Huawei HG products. An attacker may obtain information about the HG device by exploiting this vulnerability.
CVE-2018-7812
An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes security-relevant information about the state of the product, such as whether a particular operation was successful or not.
CVE-2018-7844
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus.