MacDown 0.7.1 allows directory traversal, for execution of arbitrary programs, via a file:/// or ../ substring in a shared note.
CWE-22
CVE-2019-12143
A Directory Traversal issue was discovered in SSHServerAPI.dll in Progress ipswitch WS_FTP Server 2018 before 8.6.1. An attacker can supply a string using special patterns via the SCP protocol to disclose WS_FTP usernames as well as filenames.
CVE-2019-12144
An issue was discovered in SSHServerAPI.dll in Progress ipswitch WS_FTP Server 2018 before 8.6.1. Attackers have the ability to abuse a path traversal vulnerability using the SCP protocol. Attackers who leverage this flaw could also obtain remote code execution by crafting a payload that abuses the SITE command feature.
CVE-2019-12145
A Directory Traversal issue was discovered in SSHServerAPI.dll in Progress ipswitch WS_FTP Server 2018 before 8.6.1. An attacker can supply a string using special patterns via the SCP protocol to disclose path names on the host operating system.
CVE-2019-12146
A Directory Traversal issue was discovered in SSHServerAPI.dll in Progress ipswitch WS_FTP Server 2018 before 8.6.1. Attackers have the ability to abuse a flaw in the SCP listener by crafting strings using specific patterns to write files and create directories outside of their authorized directory.
CVE-2019-11994
A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.