An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity.
CWE-287
CVE-2019-11015
A vulnerability was found in the MIUI OS version 10.1.3.0 that allows a physically proximate attacker to bypass Lockscreen based authentication via the Wallpaper Carousel application to obtain sensitive Clipboard data and the user’s stored credentials (partially). This occurs because of paste access to a social media login page.
CVE-2019-11018
applicationadmincontrollerUser.php in ThinkAdmin V4.0 does not prevent continued use of an administrator’s cookie-based credentials after a password change.
CVE-2019-10964
In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed Paradigm 515/715 pumps–All versions, MiniMed Paradigm 522/722 pumps – All versions,MiniMed Paradigm 522K/722K pumps – All versions, MiniMed Paradigm 523/723 pumps – Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps – Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps – Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only – Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
CVE-2019-10966
In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.
CVE-2019-10911
In Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, a vulnerability would allow an attacker to authenticate as a privileged user on sites with user registration and remember me login functionality enabled. This is related to symfony/security.