An authentication flaw was found in ceph in versions before 14.2.20. When the monitor handles CEPHX_GET_AUTH_SESSION_KEY requests, it doesn’t sanitize other_keys, allowing key reuse. An attacker who can request a global_id can exploit the ability of any user to request a global_id previously associated with another user, as ceph does not force the reuse of old keys to generate new ones. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.
CWE-287
CVE-2021-20238
It was found in OpenShift Container Platform 4 that ignition config, served by the Machine Config Server, can be accessed externally from clusters without authentication. The MCS endpoint (port 22623) provides ignition configuration used for bootstrapping Nodes and can include some sensitive data, e.g. registry pull secrets. There are two scenarios where this data can be accessed. The first is on Baremetal, OpenStack, Ovirt, Vsphere and KubeVirt deployments which do not have a separate internal API endpoint and allow access from outside the cluster to port 22623 from the standard OpenShift API Virtual IP address. The second is on cloud deployments when using unsupported network plugins, which do not create iptables rules that prevent to port 22623. In this scenario, the ignition config is exposed to all pods within the cluster and cannot be accessed externally.
CVE-2021-20145
Gryphon Tower routers contain an unprotected openvpn configuration file which can grant attackers access to the Gryphon homebound VPN network which exposes the LAN interfaces of other users’ devices connected to the same service. An attacker could leverage this to make configuration changes to, or otherwise attack victims’ devices as though they were on an adjacent network.
CVE-2021-20161
Trendnet AC2600 TEW-827DRU version 2.08B01 does not have sufficient protections for the UART functionality. A malicious actor with physical access to the device is able to connect to the UART port via a serial connection. No username or password is required and the user is given a root shell with full control of the device.
CVE-2021-20168
Netgear RAX43 version 1.0.3.96 does not have sufficient protections to the UART interface. A malicious actor with physical access to the device is able to connect to the UART port via a serial connection, login with default credentials, and execute commands as the root user. These default credentials are admin:admin.
CVE-2021-20092
The web interfaces of Buffalo WSR-2533DHPL2 firmware version <= 1.02 and WSR-2533DHP3 firmware version <= 1.24 do not properly restrict access to sensitive information from an unauthorized actor.