A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxureâ„¢ Control Expert (All Versions), EcoStruxureâ„¢ Process Expert (Versions prior to V2020), Modicon M340 CPU – part numbers BMXP34* (All Versions), Modicon M580 CPU – part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety – part numbers BMEP58*S and BMEH58*S (All Versions)
CWE-294
CVE-2022-44457
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.
CVE-2022-43704
The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the target device’s physical environment.
CVE-2022-42731
mfa/FIDO2.py in django-mfa2 before 2.5.1 and 2.6.x before 2.6.1 allows a replay attack that could be used to register another device for a user. The device registration challenge is not invalidated after usage.
CVE-2022-41541
TP-Link AX10v1 V1_211117 allows attackers to execute a replay attack by using a previously transmitted encrypted authentication message and valid authentication token. Attackers are able to login to the web application as an admin user.
CVE-2022-40621
Because the WAVLINK Quantum D4G (WN531G3) running firmware version M31G3.V5030.200325 and earlier communicates over HTTP and not HTTPS, and because the hashing mechanism does not rely on a server-supplied key, it is possible for an attacker with sufficient network access to capture the hashed password of a logged on user and use it in a classic Pass-the-Hash style attack.