Dataprobe iBoot-PDU FW versions prior to 1.42.06162022 contain a vulnerability where unauthenticated users could open PHP index pages without authentication and download the history file from the device; the history file includes the latest actions completed by specific users.
CWE-306
CVE-2022-31685
VMware Workspace ONE Assist prior to 22.10 contains an Authentication Bypass vulnerability. A malicious actor with network access to Workspace ONE Assist may be able to obtain administrative access without the need to authenticate to the application.
CVE-2022-31022
Bleve is a text indexing library for go. Bleve includes HTTP utilities under bleve/http package, that are used by its sample application. These HTTP methods pave way for exploitation of a node’s filesystem where the bleve index resides, if the user has used bleve’s own HTTP (bleve/http) handlers for exposing the access to the indexes. For instance, the CreateIndexHandler (`http/index_create.go`) and DeleteIndexHandler (`http/index_delete.go`) enable an attacker to create a bleve index (directory structure) anywhere where the user running the server has the write permissions and to delete recursively any directory owned by the same user account. Users who have used the bleve/http package for exposing access to bleve index without the explicit handling for the Role Based Access Controls(RBAC) of the index assets would be impacted by this issue. There is no patch for this issue because the http package is purely intended to be used for demonstration purposes. Bleve was never designed handle the RBACs, nor it was ever advertised to be used in that way. The collaborators of this project have decided to stay away from adding any authentication or authorization to bleve project at the moment. The bleve/http package is mainly for demonstration purposes and it lacks exhaustive validation of the user inputs as well as any authentication and authorization measures. It is recommended to not use bleve/http in production use cases.
CVE-2022-30515
ZKTeco BioTime 8.5.4 is missing authentication on folders containing employee photos, allowing an attacker to view them through filename enumeration.
CVE-2022-30276
The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
CVE-2022-30313
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols’ functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.