Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols’ functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service.
CWE-306
CVE-2022-30230
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions.
CVE-2022-29951
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
CVE-2022-29952
Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.
CVE-2022-29957
The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP); Cold restart (18512/UDP); SIS communications (12345/TCP); and Wireless Gateway Protocol (18515/UDP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.
CVE-2022-29877
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices allow unauthenticated access to the web interface configuration area. This could allow an attacker to extract internal configuration details or to reconfigure network settings. However, the reconfigured settings cannot be activated unless the role of an authenticated administrator user.