It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
CWE-306
CVE-2020-16102
Improper Authentication vulnerability in Gallagher Command Centre Server allows an unauthenticated remote attacker to create items with invalid configuration, potentially causing the server to crash and fail to restart. This issue affects: Gallagher Command Centre 8.30 versions prior to 8.30.1299(MR2); 8.20 versions prior to 8.20.1218(MR4); 8.10 versions prior to 8.10.1253(MR6); 8.00 versions prior to 8.00.1252(MR7); version 7.90 and prior versions.
CVE-2020-15894
An issue was discovered on D-Link DIR-816L devices 2.x before 1.10b04Beta02. There exists an exposed administration function in getcfg.php, which can be used to call various services. It can be utilized by an attacker to retrieve various sensitive information, such as admin login credentials, by setting the value of _POST_SERVICES in the query string to DEVICE.ACCOUNT.
CVE-2020-15851
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
CVE-2020-15834
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The wireless network password is exposed in a QR encoded picture that an unauthenticated adversary can download via the web-management interface.
CVE-2020-15798
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)