AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
CWE-400
CVE-2022-1783
An issue has been discovered in GitLab CE/EE affecting all versions starting from 14.3 before 14.9.5, all versions starting from 14.10 before 14.10.4, all versions starting from 15.0 before 15.0.1. It may be possible for malicious group maintainers to add new members to a project within their group, through the REST API, even after their group owner enabled a setting to prevent members from being added to projects within that group.
CVE-2022-1797
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.
CVE-2022-1821
An issue has been discovered in GitLab CE/EE affecting all versions starting from 10.8 before 14.9.5, all versions starting from 14.10 before 14.10.4, all versions starting from 15.0 before 15.0.1. It may be possible for a subgroup member to access the members list of their parent group.
CVE-2022-1708
A vulnerability was found in CRI-O that causes memory or disk space exhaustion on the node for anyone with access to the Kube API. The ExecSync request runs commands in a container and logs the output of the command. This output is then read by CRI-O after command execution, and it is read in a manner where the entire file corresponding to the output of the command is read in. Thus, if the output of the command is large it is possible to exhaust the memory or the disk space of the node when CRI-O reads the output of the command. The highest threat from this vulnerability is system availability.
CVE-2022-1677
In OpenShift Container Platform, a user with permissions to create or modify Routes can craft a payload that inserts a malformed entry into one of the cluster router’s HAProxy configuration files. This malformed entry can match any arbitrary hostname, or all hostnames in the cluster, and direct traffic to an arbitrary application within the cluster, including one under attacker control.