Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication.
CWE-613
CVE-2019-7215
Progress Sitefinity 10.1.6536 does not invalidate session cookies upon logouts. It instead tries to overwrite the cookie in the browser, but it remains valid on the server side. This means the cookie can be reused to maintain access to the account, even if the account credentials and permissions are changed.
CVE-2019-6584
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-5638
Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user’s password is changed by an administrator due to an otherwise unrelated credential leak, that user account’s current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage.
CVE-2019-5641
Rapid7 InsightVM suffers from an information exposure issue whereby, when the user’s session has ended due to inactivity, an attacker can use the Inspect Element browser feature to remove the login panel and view the details available in the last webpage visited by previous user
CVE-2019-5647
The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215.