The html-pdf package 2.2.0 for Node.js has an arbitrary file read vulnerability via an HTML file that uses XMLHttpRequest to access a file:/// URL.
CWE-668
CVE-2019-14905
A vulnerability was found in Ansible Engine versions 2.9.x before 2.9.3, 2.8.x before 2.8.8, 2.7.x before 2.7.16 and earlier, where in Ansible’s nxos_file_copy module can be used to copy files to a flash or bootflash on NXOS devices. Malicious code could craft the filename parameter to perform OS command injections. This could result in a loss of confidentiality of the system among other issues.
CVE-2019-13927
A vulnerability has been identified in Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server (All firmware versions < V6.00.320). The device contains a vulnerability that could allow an attacker to cause a denial of service condition on the device's web server by sending a specially crafted HTTP message to the web server port (tcp/80). The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device's web service. While the device itself stays operational, the web server responds with HTTP status code 404 (Not found) to any further request. A reboot is required to recover the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13546
In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the application and access unauthorized resources from the Windows operating system as the limited-access Windows user. Due to potential Windows vulnerabilities, it may be possible for additional attack methods to be used to escalate privileges on the operating system.
CVE-2019-13379
On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device’s web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults&src=RA reset and using the default credentials to get in.
CVE-2019-12928
** DISPUTED ** The QMP migrate command in QEMU version 4.0.0 and earlier is vulnerable to OS command injection, which allows the remote attacker to achieve code execution, denial of service, or information disclosure by sending a crafted QMP command to the listening server. Note: This has been disputed as a non-issue since QEMU’s -qmp interface is meant to be used by trusted users. If one is able to access this interface via a tcp socket open to the internet, then it is an insecure configuration issue.