A vulnerability in the detection engine of Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to bypass configured access control policies. The vulnerability is due to improper validation of ICMP packets. An attacker could exploit this vulnerability by sending crafted ICMP packets to the affected device. A successful exploit could allow the attacker to bypass configured access control policies.
CWE-693
CVE-2019-1669
A vulnerability in the data acquisition (DAQ) component of Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to bypass configured access control policies or cause a denial of service (DoS) condition. The vulnerability exists because the affected software improperly manages system memory resources when inspecting traffic. An attacker could exploit this vulnerability by generating specific traffic patterns for the software to inspect. A successful exploit could allow the attacker to exhaust system memory resources used for traffic inspection. Depending on the configuration, the FTD Software could fail open and cease to inspect traffic or fail closed and result in a DoS condition. This vulnerability may require manual intervention to restore the software.
CVE-2019-13924
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
CVE-2019-12938
The Roundcube component of Analogic Poste.io 2.1.6 uses .htaccess to protect the logs/ folder, which is effective with the Apache HTTP Server but is ineffective with nginx. Attackers can read logs via the webmail/logs/sendmail URI.
CVE-2019-10328
Jenkins Pipeline Remote Loader Plugin 1.4 and earlier provided a custom whitelist for script security that allowed attackers to invoke arbitrary methods, bypassing typical sandbox protection.
CVE-2019-1003030
A sandbox bypass vulnerability exists in Jenkins Pipeline: Groovy Plugin 2.63 and earlier in pom.xml, src/main/java/org/jenkinsci/plugins/workflow/cps/CpsGroovyShell.java that allows attackers able to control pipeline scripts to execute arbitrary code on the Jenkins master JVM.