Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV340 and RV345 Routers could allow an authenticated, remote attacker to inject and execute arbitrary commands on the underlying operating system of an affected device. These vulnerabilities are due to insufficient validation of user-supplied input. An attacker could exploit these vulnerabilities by sending malicious input to an affected device. A successful exploit could allow the attacker to execute arbitrary commands on the underlying Linux operating system of the affected device. To exploit these vulnerabilities, an attacker would need to have valid Administrator credentials on the affected device.
CWE-77
CVE-2022-20665
A vulnerability in the CLI of Cisco StarOS could allow an authenticated, local attacker to elevate privileges on an affected device. This vulnerability is due to insufficient input validation of CLI commands. An attacker could exploit this vulnerability by sending crafted commands to the CLI. A successful exploit could allow the attacker to execute arbitrary code with the privileges of the root user. To exploit this vulnerability, an attacker would need to have valid administrative credentials on an affected device.
CVE-2022-20054
In ims service, there is a possible AT command injection due to a missing permission check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06219083; Issue ID: ALPS06219083.
CVE-2022-1509
Sed Injection Vulnerability in GitHub repository hestiacp/hestiacp prior to 1.5.12. An authenticated remote attacker with low privileges can execute arbitrary code under root context.
CVE-2022-1030
Okta Advanced Server Access Client for Linux and macOS prior to version 1.58.0 was found to be vulnerable to command injection via a specially crafted URL. An attacker, who has knowledge of a valid team name for the victim and also knows a valid target host where the user has access, can execute commands on the local system.
CVE-2022-0902
Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’), Improper Neutralization of Special Elements used in a Command (‘Command Injection’) vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.