An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file.The destination buffer sp+0x440 is overflowed with the call to sprintf() for any type values that are greater than 1024-len(‘/etc/config-tools/config_interfaces interface=X1 state=enabled config-type=‘) in length. A type value of length 0x3d9 will cause the service to crash.
CWE-787
CVE-2019-5185
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service “I/O-Check” functionality of WAGO PFC 200. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1ea28 the extracted state value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state= using sprintf(). The destination buffer sp+0x40 is overflowed with the call to sprintf() for any state values that are greater than 512-len(“/etc/config-tools/config_interfaces interface=X1 state=”) in length. Later, at 0x1ea08 strcpy() is used to copy the contents of the stack buffer that was overflowed sp+0x40 into sp+0x440. The buffer sp+0x440 is immediately adjacent to sp+0x40 on the stack. Therefore, there is no NULL termination on the buffer sp+0x40 since it overflowed into sp+0x440. The strcpy() will result in invalid memory access. An state value of length 0x3c9 will cause the service to crash.
CVE-2019-5186
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service “I/O-Check” functionality of WAGO PFC 200. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1eb9c the extracted interface element name from the xml file is used as an argument to /etc/config-tools/config_interfaces interface= using sprintf(). The destination buffer sp+0x40 is overflowed with the call to sprintf() for any interface values that are greater than 512-len(“/etc/config-tools/config_interfaces interface=”) in length. Later, at 0x1ea08 strcpy() is used to copy the contents of the stack buffer that was overflowed sp+0x40 into sp+0x440. The buffer sp+0x440 is immediately adjacent to sp+0x40 on the stack. Therefore, there is no NULL termination on the buffer sp+0x40 since it overflowed into sp+0x440. The strcpy() will result in invalid memory access. An interface value of length 0x3c4 will cause the service to crash.
CVE-2019-5187
An exploitable out-of-bounds write vulnerability exists in the TIFreadstripdata function of the igcore19d.dll library of Accusoft ImageGear 19.5.0. A specially crafted TIFF file file can cause an out-of-bounds write, resulting in a remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability.
CVE-2019-5188
A code execution vulnerability exists in the directory rehashing functionality of E2fsprogs e2fsck 1.45.4. A specially crafted ext4 directory can cause an out-of-bounds write on the stack, resulting in code execution. An attacker can corrupt a partition to trigger this vulnerability.
CVE-2019-5105
An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System).