Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS Safety Manager hardcoded credentials issue. The affected components are characterized as: POLO bootloader. The potential impact is: Manipulate firmware. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 serial interface for firmware management purposes. When booting, the Safety Manager exposes the Enea POLO bootloader via this interface. Access to the boot configuration is controlled by means of credentials hardcoded in the Safety Manager firmware. The credentials for the bootloader are hardcoded in the firmware. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize these credentials to control the boot process and manipulate the unauthenticated firmware image (see FSCT-2022-0054).
CWE-798
CVE-2022-30318
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
CVE-2022-30234
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30036
MA Lighting grandMA2 Light has a password of root for the root account. NOTE: The vendor’s position is that the product was designed for isolated networks. Also, the successor product, grandMA3, is not affected by this vulnerability.
CVE-2022-29953
The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality.
CVE-2022-29960
Emerson OpenBSI through 2022-04-29 uses weak cryptography. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. DES with hardcoded cryptographic keys is used for protection of certain system credentials, engineering files, and sensitive utilities.