Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.
CWE-798
CVE-2020-12376
Use of hard-coded key in the BMC firmware for some Intel(R) Server Boards, Server Systems and Compute Modules before version 2.47 may allow authenticated user to potentially enable information disclosure via local access.
CVE-2020-12110
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
CVE-2020-12035
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration.
CVE-2020-12039
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v’s6.x model 35700BAX & Baxter Spectrum Infusion System v’s8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.
CVE-2020-12045
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.