An issue was discovered in svc-login.php in Void Aural Rec Monitor 9.0.0.1. Passwords are stored in unencrypted source-code text files. This was noted when accessing the svc-login.php file. The value is used to authenticate a high-privileged user upon authenticating with the server.
CWE-798
CVE-2021-25275
SolarWinds Orion Platform before 2020.2.4, as used by various SolarWinds products, installs and uses a SQL Server backend, and stores database credentials to access this backend in a file readable by unprivileged users. As a result, any user having access to the filesystem can read database login details from that file, including the login name and its associated password. Then, the credentials can be used to get database owner access to the SWNetPerfMon.DB database. This gives access to the data collected by SolarWinds applications, and leads to admin access to the applications by inserting or changing authentication data stored in the Accounts table of the database.
CVE-2021-24005
Usage of hard-coded cryptographic keys to encrypt configuration files and debug logs in FortiAuthenticator versions before 6.3.0 may allow an attacker with access to the files or the CLI configuration to decrypt the sensitive data, via knowledge of the hard-coded key.
CVE-2021-23842
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device’s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
CVE-2021-23233
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
CVE-2021-22707
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.