StackStorm before 3.4.1, in some situations, has an infinite loop that consumes all available memory and disk space. This can occur if Python 3.x is used, the locale is not utf-8, and there is an attempt to log Unicode data (from an action or rule name).
CWE-835
CVE-2021-28676
An issue was discovered in Pillow before 8.2.0. For FLI data, FliDecode did not properly check that the block advance was non-zero, potentially leading to an infinite loop on load.
CVE-2021-28484
An issue was discovered in the /api/connector endpoint handler in Yubico yubihsm-connector before 3.0.1 (in YubiHSM SDK before 2021.04). The handler did not validate the length of the request, which can lead to a state where yubihsm-connector becomes stuck in a loop waiting for the YubiHSM to send it data, preventing any further operations until the yubihsm-connector is restarted. An attacker can send 0, 1, or 2 bytes to trigger this.
CVE-2021-27918
encoding/xml in Go before 1.15.9 and 1.16.x before 1.16.1 has an infinite loop if a custom TokenReader (for xml.NewTokenDecoder) returns EOF in the middle of an element. This can occur in the Decode, DecodeElement, or Skip method.
CVE-2021-27565
The web server in InterNiche NicheStack through 4.0.1 allows remote attackers to cause a denial of service (infinite loop and networking outage) via an unexpected valid HTTP request such as OPTIONS. This occurs because the HTTP request handler enters a miscoded wbs_loop() debugger hook.
CVE-2021-27385
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7″ & 15″ (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4" – 22" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4" – 22" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.